HMX Long Cased Axial Fans

HMX Long Cased Axial Fans

Suitable for ATEX Zone 1 & 2 Gas, or Zone 22 Dust Environments

Manufacturing Features:
ATEX Certified Construction: Ex h - IIC & IIB+H2 Gas and IIIB Dusts.
Long cased axial fan with reinforced, steel fan casing.

Polyester powder coated finish.
Motor-impeller modular assembly for complete versatility.
Cast aluminum impeller with variable pitch angle.
ATEX standard asynchronous motor.
ATEX certified: II2G Ex d, Ex e / II3G Ex nA.IP55 protection and class F insulation.

Manufactured with standard voltages: 230/400V 50Hz in 3~ motors up to 4kW and 400/690V 50Hz for higher powers.

The ATEX rated series of HMX axial fans suitable for hazardous atmospheres

Offer Explosion Protection in Zone 1 & 2 Gas, or Zone 22 Dust Environments

HMX long cased axial fans provide increased mechanical strength and corrosive resistance. They feature a cast aluminium impeller and reinforced, steel fan casing with a polyester powder coated finish. HMX axial fans are designed for wall or duct installation and suitable for a wide range of industrial applications.

Motor-Impeller Modular Assembly for Complete Versatility

Featuring adjustable blades, the HMX series of long cased axial fans can provide a wide range of duties with precise and controlled higher airflow rates.

Available Fan Types

HM: Polypropylene impeller (A2 profile) or polyamide impeller reinforced with fibreglass (other profiles) with variable pitch angle.

HMA: Cast aluminium impeller with variable pitch angle.

HMX: Cast aluminium impeller ATEX ratedATEX rated fans

Suitable Applications

Designed for wall or duct installation, they are suitable for:
• Air renewal in buildings and industries
• Smoke extraction (max 40ºC)
• Maximum working temperature: ambient from -20ºC to 40ºC
• Ventilation in indoor environments classified as ATEX

Available on Request

• B-form or 100% reversible impeller
• 60Hz fans and special voltages

Technical Data

HMX fan models are paired with an ATEX standard asynchronous motor manufactured with standard voltages: 230/400V 50Hz in three phase motors up to 4kW and 400/690V 50Hz for higher powers.

Fan Type Voltage
(V)
Frequency
(Hz)
Input
Power (kW)
Rated
Current (A)
Speed
(rpm)
Max Temp
(°C)
IP Rating
(IP)
GKHM 355-CIG.102.5HF IE Gen3 (IE5) 3~ 380-480 50 / 60 2.33 3.7 at 400V 3120 40 IP54
GKHM 400-CIG.114.6FF IE Gen3 (IE5) 3~ 380-480 50 / 60 4.48 7 at 400V 3170 40 IP54
GKHM 450-CIG.128.6IF IE Gen3 (IE4) 3~ 380-480 50 / 60 5.9 9.05 at 400V 2950 40 IP54
GKHM 500-CIG.143.6NA IE Gen3+ (IE4) 3~ 380-480 50 / 60 7.48 11.4 at 400V 2625 40 IP54
GKHM 560-CIG.160.6NA IE Gen3+ (IE4) 3~ 380-480 50 / 60 6.85 10.7 at 400V 2125 40 IP54
GKHM 630-CIG.180.6NA IE Gen3+ (IE4) 3~ 380-480 50 / 60 5.1 7.88 at 400V 1580 40 IP54